AUM 2, AUM 2K with lever mixer

AUM 2 is an automatic sensor-controlled tap for sinks with the possibility of setting the water-flow and temperature by a lever mixer. Water turns on automatically when the user’s hands are within the sensor’s range and turns off when they have been removed. Water keeps on running for a short period of time after the hands have been removed from the scanning zone – after-flow delay time. The water stops flowing automatically if the sensor has been screened for longer than 30 seconds.
The easy setting of the temperature and flow of water is controlled by a lever mixer according to the individual requirements of each customer. The water cannot flow when the lever mixer is fully lowered. The arm of the tap is rotary.
The type version of the tap AUM 2 is the tap AUM 2K with shorter outflow arm. Other characteristics and functionality of tap are same as with AUM 2.
Automatic sensor-controlled taps AUM 2 and AUM 2K meet EU standards and are intended for facilities where the user’s comfort and the maintenance of hygiene is required at maximum water savings.

Package contents

  • tap with lever mixer
  • photocell head
  • electronics with a holder for hanging
  • electromagnetic valve – 2 pcs
  • corner valve with filter – 2 pcs
  • battery holder (AUM 2.B, AUM 2K.B)
  • cylindrical batteries 1,5 V (AUM 2.B, AUM 2K.B) – 4 pcs
  • connecting hoses
  • fixing strap
  • M8 screw with nut and pads
  • tube with silicon mastic

ZAC – power supply

Product code Product name Price Price (VAT)
AUM 2 On demand On demand
AUM 2.B On demand On demand
AUM 2K On demand On demand
AUM 2K.B On demand On demand
Radius of sensor self adjusting
Water inlet G 1/2“
Water pressure 0,2 – 0,8 MPa (AUM 2.B, AUM 2K.B)
0,1 – 1,0 MPa (AUM 2, AUM 2K)
Diameter of installation opening in washbasin min. 33 mm
Adjustable time of water flow 1 – 4 sec. (adjusted to 1 sec.)
Power supply 12 V, 50 Hz (AUM 2, AUM 2K)
6 V DC (AUM 2.B, AUM 2K)
Power requirement 10VA (AUM 2, AUM 2K)
Source of power supply ZAC 1/20 (max. 2x AUM 2, AUM 2K)
ZAC 1/50 (max. 5x AUM 2, AUM 2K)
batteries – 1,5 V (AUM 2.B, AUM 2K.B) – 4 pcs.
Operating life of batteries approximately 1,5 years at 100 operations a day
Weight 2,5 kg
  • Set-up water inlet, pipe 1/2“ – as per picture
  • Set-up outlet – as per siphon
  • Set-up cable for power supply – 12 V, 50 Hz from source of power supply ZAC (does not apply to AUM 2.B, AUM 2K.B)
  • Ceramics of the washbasin assembled as per picture

  • AUM 2
    sensor controlled tap connected to hot and cold water

  • AUM 2K
    sensor controlled tap connected to hot and cold water

Manual

Data for projectants

Manuals